Home | About Us | Above Ground Tanks | Below Ground Tanks | Valves/Fittings/Lids | Couplers & Adapters | Hose/Pumps | Accessories | Material Handling Carts | Fork Lift Containers | Pumper Products | Baffle Ball | Clearance/Used Tanks | All Products | New Products | Directions | Contact Us | Make a Referral

Kentucky Tank

Cistern Installation

 

 

CISTERN TANK INSTALLATION PROCEDURES

1. Excavation

  • Backfill cover (A) may range from 6" to 30"
  • Sidewall and end wall allowance (B) should be 18" to 24"
  • Bedding (C) should be a well compacted sand/gravel mixture: 6" minimum in soil terrain, 12" minimum in rock terrain.
CISTERN TANK INSTALLATION PROCEDURES

2. Lid and Manhole Extension

  • For proper fit, install the lid and/or manhole extension before you put water in the tank and backfill.
  • Please note the direction of flow - the inlet is higher than the outlet.
CISTERN TANK INSTALLATION PROCEDURES

3. Installation of Bulkhead Fittings

  • Install bulkhead fitting in either side of manway or end rib as shown.
  • Tank must be vented.
  • Tank lid includes gasket and stainless steel screws for water-tight seal.
CISTERN TANK INSTALLATION PROCEDURES

4. Backfilling Exterior and Filling with   Water

  • CAUTION: Start filling the tank with water when you begin to backfill, keeping the water level even with the backfill level as you go.
  • Backfill in 12" maximum layers with a well compacted sand/gravel mixture. ALWAYS COMPACT ENDS FIRST.
  • Tamp and compact backfill under inlet and outlet pipe.
CISTERN TANK INSTALLATION PROCEDURES

5. Backfilling the Top of Tank

  • Once the tank is filled with water, backfill to the surrounding level to a maximum of 30".

General Notes

  • Do not install tank in water-saturated clay or in high water  table.
  • Do not install tank across the path of vehicles or heavy equipment.
  • The tanks are designed for below ground use only.
  • For a water-tight seal, lid must be sealed with silicone caulking.
  • Cistern tanks should remain one-fourth full at all times.

Failure to comply with Kentucky Tank's installation procedures and general notes will void the warranty.